CS INSTRUMENTS FA 515 Dew point sensor for refrigeration dryers incl. factory certificate, 4...20 mA
Die Taupunktsensoren von CS Instruments sind speziell für die Feuchtemessung in Kältetrocknern entwickelt und steigern die Energieeffizienz sowie die Produktqualität in Druckluftsystemen. Dank fortschrittlicher Sensorik und einem robusten Design bieten sie präzise Messergebnisse und erhöhen die Lebensdauer durch Schutz vor Kondensation und Verschmutzung.
CS Instruments
As a leading manufacturer of compressed air measurement technology, CS INSTRUMENTS stands for highest quality and innovation. "Made in Germany" is our practice - development, production, and calibration take place exclusively in Germany.
FA 515 dew point sensor for refrigeration dryers with IO-Link interface
The IO-Link interface makes it easier to integrate the dew point measurement into machines and systems. An integrated pressure sensor is also available as an option. The dew point sensors have been specially developed for measuring humidity in refrigeration dryers and play a crucial role in monitoring compressed air systems. Precise monitoring is necessary to increase energy efficiency, ensure product quality, protect machines from damage, detect maintenance requirements at an early stage and thus enable cost savings. These factors contribute to the smooth operation of compressed air systems in various industrial applications.
The dew point sensors from CS Instruments benefit from continuous improvements in sensor technology and evaluation electronics, resulting in higher precision at different ambient temperatures and improved signal resolution. Despite these technical advancements, the new sensors, like their predecessors, offer stable and reliable measurement results over a long period of time. The robust sensor element is insensitive to condensation and is protected from direct contact with contaminated particles by a stainless steel sintered cap, which significantly extends the service life and reliability of the sensors.
Measuring range | -20…50 °Ctd |
Accuracy | ± 1 °C at +50...-20 °Ctd / ± 2 °C at -20...-50 °Ctd / ± 3 °C at -50...-80 °Ctd |
Pressure range (bar) | -1...50, special version up to 500 |
Power supply | 24 VDC (10…36 VDC) |
Protection class | IP 66 |
EMC | Nach DIN EN 61326-1 |
Screw-in thread | G 1/2″ Edelstahl, Optional: UNF 5/8″, NPT 1/2″ |
Operating temperature (°C) | -20…70 |
Connection | M12, 5-polig |
PC connection | Modbus-RTU Schnittstelle (RS 485) |
Analogue output | 4…20 mA Analogausgang (2-Draht-Technik) oder Modbus RTU Schnittstelle |
Load for analogue output | < 500 Ω |
Dimensions | Ø 30 mm, length approx. 130 mm |